China Suppliers Miniaturized Compact 10kV Prefabricated Substation Factory for Urban Power Distribution Solutions
Flexible Grid Connection and System Compatibility Capabilities
Configurable fully insulated and fully sealed ring network cabinet units, enabling advanced power supply modes such as dual-ring network and single-ring network. Each unit is connected through prefabricated cables, forming a complete ring network system. In the event of a fault in any section of the line, it can be quickly isolated and power restored, with power reliability reaching 99.99%.
It can provide a complete dual power access solution for important users, equipped with an automatic transfer switch (ATS) and corresponding protection systems. When the main power supply fails, the backup power can be automatically switched on within an extremely short period of time, ensuring uninterrupted power supply for critical loads such as hospitals, data centers, and important production lines.
To meet the radial power supply requirements of ordinary users, an economical and efficient standardized configuration solution is provided. On the high-voltage side, a load switch-fuse combination electrical apparatus can be used to protect the transformer. On the low-voltage side, intelligent frame circuit breakers and molded case circuit breakers are configured to form a complete protection system.
Adopting a modular design concept, standard interfaces are reserved for electrical wiring. When the user's load increases in the future, it can be expanded quickly by replacing the transformer module or increasing the capacity of the low-voltage cabinet module. This design reduces the expansion cost during the product's life cycle by more than 50%.
Product Specifications
| Name | Unit | High-voltage electrical cabinet | Transformer | Low-voltage electrical cabinet |
|---|---|---|---|---|
| nominal voltage | KV | 10 | 10/0.4 | 0.4 |
| rated current | A | 630 | - | 100~2500 |
| rated frequency | Hz | 50 | 50 | 50 |
| rated capacity | KVA | - | 100~1250 | - |
| Rated thermal stability current | kA | 20/4S | - | 30/15 |
| Rated dynamic stable current (peak) | kA | 50 | - | 63 |
| Rated closing short-circuit current (peak) | kA | 50 | - | 15~30 |
| Rated breaking short-circuit current | kA | 31.5 | - | - |
| Rated starting load current | A | 630 | - | - |
| lmin power frequency withstand voltage | kA | Intergranular 42 fracture surfaces between 48 layers | 35/28(5min) | 20/2.5 |
| lightning impulse withstand voltage | kA | Intergranular 42 fracture surfaces between 48 layers | 75 | - |
| Shell protection grade | - | IP23 | IP23 | IP23 |
| Noise level | dB | - | Oil transformer<55, Dry transformer≤65 | - |
| loop number | amount | 1~6 | - | 4~30 |
| Maximum reactive power compensation on the low-voltage side | kvar | - | - | 300 |
Detail Pictures
Frequently Asked Questions (FAQ)
What is the power reliability rate of the complete ring network solution?
The complete ring network solution features configurable fully insulated and fully sealed ring network units connected via prefabricated cables, reaching an operational power reliability of 99.99%.
How does the dual power automatic switching system perform during outages?
The system utilizes an automatic transfer switch (ATS) that switches to backup power within an extremely short duration if the primary supply fails, ensuring seamless operation for hospitals, data centers, and critical manufacturing facilities.
What is the rated capacity range for the transformer module?
The transformer operates at a nominal voltage of 10/0.4 KV and supports a flexible rated capacity ranging from 100 KVA to 1250 KVA at a rated frequency of 50 Hz.
What are the noise levels and enclosure protection standards?
The entire system holds an IP23 protection grade. The noise levels are strictly managed below 55 dB for oil-immersed transformers and 65 dB or less for dry-type transformers.
How does the modular design reduce lifecycle expansion costs?
With standard pre-reserved wiring interfaces, users can quickly upgrade load capacities by replacing the transformer module or expanding low-voltage cabinets, reducing lifecycle expansion costs by more than 50%.