110kV 10000kVA Outdoor Oil Immersed Power Transformer from China Suppliers and Factory for Power Substation
Product Application
Low-noise environmental-friendly design, suitable for various scenarios
Low-noise operation is achieved through structural optimization and process improvement. The core is made using a high-precision stacking process, combined with an elastic clamping structure, which reduces core vibration and magnetic expansion noise. The winding is tightly wound and the size is stabilized through constant pressure drying treatment, thereby reducing electromagnetic vibration noise. A low-noise cooling fan (air-cooled type) is selected. The fan starts and stops automatically based on oil temperature and load, further reducing operating noise.
Compact structure and lightweight design, saving infrastructure costs
Based on the electromagnetic optimization design concept, the structure is streamlined to the greatest extent while ensuring performance. The layout of the engine body and the dimensions of components are optimized, resulting in a 15%–20% reduction in the equipment's volume compared to traditional products, and a corresponding weight reduction, achieving a lightweight design. An integrated structure design is adopted to reduce redundant components and improve space utilization. This not only lowers transportation difficulty and costs but also saves installation area, especially suitable for installation scenarios with limited space such as urban cores, tunnels, and subways.
High-quality insulation configuration, with outstanding electrical performance
Completely use high-quality insulating materials. The insulating components are made of high-strength insulating materials such as high-quality laminated wood and epoxy glass tape, which will not crack or deform even under short-circuit electric force, and can maintain stability.
Highly intelligent and adaptable, meeting the upgrade requirements of the power grid
Deeply integrated into the intelligent power grid construction system, it has a complete intelligent monitoring and control interface, enabling real-time collection and remote transmission of key operating parameters such as oil temperature, oil level, voltage, and current. Equipped with intelligent protection devices, including pressure release valves, temperature controllers, and oil level alarms, when equipment experiences overheating, overpressure, or abnormal oil levels, it can promptly issue alerts and trigger protection actions to prevent the expansion of faults. It supports coordinated operation with new energy power generation systems and energy storage equipment, possesses flexible power regulation and voltage adaptation capabilities, and helps with the grid connection and absorption of distributed energy.
Product Specifications
| Rated Capacity (KVA) | Voltage Combination (KV) | Connection Group Table | No-Load Loss (W) | Load Loss (W) 75° | No-Load Current (%) | Short Circuit Impedance (%) | ||
| H.V. (KV) | High-Voltage Tapping Range | L.V. (KV) | ||||||
| 2000 | 35 | ±3×2.5% | 6.3 / 10.5 | Yd11 | 2300 | 19240 | 0.8 | 6.5 |
| 2500 | 2720 | 20640 | 0.8 | |||||
| 3150 | 35 / 38.5 | ±3×2.5% | 6.3 / 10.5 | 3230 | 24710 | 0.72 | 7.0 | |
| 4000 | 3870 | 29160 | 0.72 | |||||
| 5000 | 4640 | 34200 | 0.68 | |||||
| 6300 | 5630 | 46770 | 0.68 | 7.5 | ||||
| 8000 | 35 / 38.5 | ±3×2.5% | 6.3 / 6.6 / 10.5 / 11 | Ynd11 | 7870 | 40610 | 0.6 | |
| 10000 | 9280 | 48050 | 0.6 | |||||
| 12500 | 10940 | 56860 | 0.56 | 8.0 | ||||
| 16000 | 13170 | 70320 | 0.54 | |||||
| 20000 | 15570 | 82780 | 0.54 | |||||
Detail Pictures
Frequently Asked Questions
Q
What rated capacity range does this oil-immersed transformer cover?
This oil-immersed transformer series covers a rated capacity range from 2,000 KVA to 20,000 KVA, making it suitable for a wide variety of power distribution applications including industrial, commercial, and utility-scale projects.
Q
How does the low-noise design benefit installation in urban or sensitive environments?
The transformer uses a high-precision core stacking process with an elastic clamping structure to minimize vibration and magnetic noise. Combined with a low-noise auto-controlled cooling fan, it is well-suited for noise-sensitive locations such as urban cores, tunnels, subways, and residential areas.
Q
How much smaller is this transformer compared to traditional models?
Through electromagnetic optimization and integrated structural design, this transformer achieves a 15%–20% reduction in volume compared to traditional products. The reduced footprint and lighter weight make it especially suitable for space-constrained installation environments.
Q
What insulation materials are used, and how do they ensure long-term reliability?
The transformer uses high-strength insulating materials including high-quality laminated wood and epoxy glass tape. These materials are engineered to resist cracking and deformation even under short-circuit electric forces, ensuring consistent electrical performance and long-term operational stability.
Q
What intelligent monitoring and protection features are included?
The transformer is equipped with a full intelligent monitoring interface that enables real-time collection and remote transmission of parameters such as oil temperature, oil level, voltage, and current. Protection devices include pressure release valves, temperature controllers, and oil level alarms that automatically trigger alerts and protective actions in case of overheating, overpressure, or abnormal oil levels.
Q
Is this transformer compatible with renewable energy and distributed energy systems?
Yes. The transformer supports coordinated operation with new energy power generation systems and energy storage equipment. It features flexible power regulation and voltage adaptation capabilities, enabling seamless grid connection and efficient absorption of distributed and renewable energy sources.