China Suppliers Factory Offering Low Noise Eco-Friendly 10kV Prefabricated Substation for Residential Areas
-
๐1. Multi-layer Physical Protection System
The box body adopts anti-theft design, and the door lock has anti-picking function. Mechanical interlock or electrical interlock is set in the high-voltage room and the low-voltage room respectively, strictly preventing accidental entry into the energized compartments. The transformer room is equipped with an independent pressure relief channel, which can quickly release pressure in case of a fault, ensuring the safety of personnel and equipment.
-
๐ก2. Intelligent Monitoring and Early Warning
An optional intelligent monitoring system can be equipped. It can monitor parameters such as transformer temperature, load rate, key node temperature, access status, and environmental temperature and humidity in real time. The data is transmitted wirelessly to the monitoring center, enabling remote operation and fault early warning, transforming "scheduled maintenance" into "condition-based maintenance".
-
๐ง3. Humanized Maintenance Design
Each functional room is equipped with an independent maintenance door, and the width of the maintenance passage complies with safety standards. The high-voltage cable heads are designed with a touchable feature, allowing for safe operation without the need for special tools during maintenance. The main components are all designed with front maintenance features, enabling all maintenance operations to be completed from the front.
-
๐4. Quick Relocation and Reuse
The bottom of the box is equipped with standard lifting holes and transportation fixation points, allowing for overall handling using general lifting equipment. During relocation, only the incoming and outgoing cable connections need to be disconnected, significantly enhancing the equipment's utilization rate and return on investment. It is particularly suitable for the rental market and temporary power supply scenarios.
| Name | Unit | High-Voltage Electrical Cabinet | Transformer | Low-Voltage Electrical Cabinet |
|---|---|---|---|---|
| Nominal Voltage | KV | 10 | 10/0.4 | 0.4 |
| Rated Current | A | 630 | โ | 100~2500 |
| Rated Frequency | Hz | 50 | 50 | 50 |
| Rated Capacity | KVA | โ | 100~1250 | โ |
| Rated Thermal Stability Current | kA | 20/4S | โ | 30/15 |
| Rated Dynamic Stable Current (Peak) | kA | 50 | โ | 63 |
| Rated Closing Short-Circuit Current (Peak) | kA | 50 | โ | 15~30 |
| Rated Breaking Short-Circuit Current | kA | 31.5 | โ | โ |
| Rated Starting Load Current | A | 630 | โ | โ |
| 1min Power Frequency Withstand Voltage | kA | Intergranular 42 / fracture surfaces between 48 layers | 35/28 (5min) | 20/2.5 |
| Lightning Impulse Withstand Voltage | kA | Intergranular 42 / fracture surfaces between 48 layers | 75 | โ |
| Shell Protection Grade | โ | IP23 | IP23 | IP23 |
| Noise Level | dB | โ | Oil transformer <55 / Dry transformer โค65 | โ |
| Loop Number | Amount | 1~6 | โ | 4~30 |
| Maximum Reactive Power Compensation on Low-Voltage Side | kvar | โ | โ | 300 |