10 kV 500 kVA Outdoor Power Distribution Transformer - China Suppliers Factory for Reliable Voltage Regulation
The key lies in using high magnetic conductivity grain-oriented cold-rolled silicon steel sheets, preferably in the ultra-thin 0.20mm specification. Their magnetic permeability can reach 1.93T, with the easily magnetized structure accounting for over 95%. This reduces magnetic hysteresis loss from the source. During production, the 45° full inclined seam holeless stacking process and the horizontal five-step laminating technology are adopted, combined with the core column epoxy glass tape binding reinforcement. This minimizes the magnetic circuit gap and leakage loss to the greatest extent. Compared with traditional S9 series products, the average no-load loss is reduced by more than 30%, the no-load current decreases by 70%-85%, and even during long-term light-load operation, significant energy savings can be achieved.
The windings are made of high-purity oxygen-free copper electromagnetic wire, which undergoes special surface treatment to ensure the smoothness and absence of burrs on the wire, effectively reducing the resistance and eddy current losses. According to the capacity requirements, multi-layer cylindrical, intertwined continuous, or inner shielded winding structures are adopted. For large-capacity products, composite wires are also used. By optimizing the arrangement of the wire buns and the distribution of ampere-turns, the winding current is evenly distributed, reducing local overheating and concentrated losses.
Equipped with a high-precision on-load voltage regulating switch, a separate voltage regulating winding is specially designed. The axial dimensions and magnetic center of each winding are strictly controlled to ensure stable electromagnetic balance during the voltage regulation process. It can smoothly switch the tap position within the range of 0 to 100% of the rated load. The voltage regulation accuracy is ±2.5%, and it can quickly respond to voltage fluctuations in the power grid and precisely maintain the output voltage within the set range.
| Rated Capacity (KVA) | Connection Group Label | Voltage Combination (KV) | No-Load Current (%) | Load Loss (T) | No-Load Loss (T) | Short Circuit Impedance (%) | ||
| (H.V.) | High-Voltage Tapping Range | (L.V.) | ||||||
| 50 | Dyn11 Yyn0 |
35 38.5 |
±5% ±2×2.5% |
0.4 | 1.30 | 2100/1140 | 130 | 6.5 |
| 100 | 1.10 | 2010/1910 | 185 | |||||
| 125 | 1.10 | 2370/2260 | 215 | |||||
| 160 | 1.00 | 2820/2680 | 225 | |||||
| 200 | 1.00 | 3320/3160 | 270 | |||||
| 250 | 0.95 | 3950/3760 | 320 | |||||
| 315 | 0.95 | 4750/4530 | 385 | |||||
| 400 | 0.85 | 5740/5470 | 465 | |||||
| 500 | 0.85 | 6910/6580 | 545 | |||||
| 630 | 0.65 | 7860 | 665 | |||||
| 800 | 0.65 | 9400 | 785 | |||||
| 1000 | 0.65 | 11500 | 920 | |||||
| 1250 | 0.60 | 13900 | 1120 | |||||
| 1600 | 0.60 | 16600 | 1350 | |||||
| 2000 | 0.55 | 19700 | 1590 | |||||
| 2500 | 0.55 | 23200 | 1890 | |||||