KYN28-12 Armored Withdrawable AC Metal-Enclosed Switchgear from China Suppliers and Factory for Power Grids
Basic Product Overview
KYN28-12 high-voltage switchgear cabinet (labeled as — feeder cabinet) is a mainstream indoor metal-clad switchgear widely used in 10kV power distribution systems. As a core device in medium-voltage power grids, it undertakes the tasks of power receiving, distribution, fault protection, and operational monitoring, and is widely applied in substations, industrial and mining enterprises, commercial buildings, and urban power distribution networks.
The KYN28-12 cabinet (also known as "KYN28A-12") adopts a withdrawable, compartmentalized metal-enclosed structure (complying with GB3906-2020 and IEC 62271-200 standards). Its design separates the cabinet into independent functional compartments through grounded metal partitions:
▪ Circuit Breaker Compartment ▪ Busbar Compartment ▪ Cable Compartment ▪ Secondary Control Compartment
This compartmentalized design not only prevents fault expansion between compartments but also improves the safety of operation and maintenance. The cabinet is a "feeder cabinet" (responsible for distributing power from the main busbar to downstream equipment or lines), marked with the model "KYN28-12" (applicable to 12kV systems) on the top panel.
Application Scenarios
Core Technical Parameters
| Parameter | Specification / Value |
|---|---|
| ⚡ Rated Voltage | 12kV (adapted to 10kV power systems; maximum operating voltage: 12kV) |
| ⚡ Rated Frequency | 50Hz (matches the standard power grid frequency in most countries and regions) |
| ⚡ Rated Current — Main Circuit | 630A, 1000A, 1250A, 1600A (feeder scenarios typically use 630A / 1250A) |
| ⚡ Rated Current — Auxiliary Circuit | 220V / 380V (for powering control, protection, and monitoring components) |
| ⚡ Short-Time Withstand Current | ≥ 25kA (duration: 4s; withstands steady-state short-circuit current impact) |
| ⚡ Peak Withstand Current | ≥ 63kA (resists instantaneous peak current generated by short-circuit faults) |
| ⚡ Power Frequency Withstand Voltage | 42kV / 1 min (between live parts and ground; between different phases) |
| ⚡ Lightning Impulse Withstand Voltage | 75kV (protects against overvoltage caused by lightning strikes or switching operations) |
| ⚡ IP Protection Grade | IP4X standard (IP54 available for harsh environments) |
| ⚡ Operating Temperature | -10°C to +40°C (derating by 1% per 1°C above 40°C) |
| ⚡ Altitude | ≤ 1000m (derating required above 1000m) |
| ⚡ Humidity | Daily average ≤ 95%, monthly average ≤ 90% (no condensation) |
Detail Pictures